amh chillers for temperatures from 0°C to 60°C

amcoss amh chillers do cover a temperature range from 0 °C – 60 °C. amcoss offers special, adapted and already qualified chillers. They do, for example, replace LAM Dual Loop as well as AMAT Centura chillers and are mainly used for cooling and climatizing chambers and ozon generators but also for electrodes and electrostatic chucks.

The advantage of our devices lies in their customer-specific adaptation. That means that the standardized interface is being replaced by a proprietary interface. Even other individual configurations (e.g. conductivity measurement) are possible. So amcoss customers no longer have to find their own solutions. We supply a ready-to-use device.

Chillers for temperature range 5–60°C

amh-024 / amh-024-ac

Water-cooled or air-cooled (ac) version. Proven SMC chiller adapted to replace LAM Chillers

LAM TCU4080

amh-024-R / amh-030-R

Water-cooled or air-cooled (ac) version. 2 proven SMC chillers placed in a special rack adapted to replace LAM Chillers

LAM TCU2080 (dual loop)

amh-030 / amh-030-R

Water-cooled or air-cooled (ac) version. Proven SMC chiller adapted to replace

Betta Tech CU700

amh-050 / amh-060

Proven water-cooled SMC chillers adapted to replace AMAT Centura Chillers

Neslab HX150 (CHX)
Neslab HX300

An optional tray for placing of external DI water cartridge mounted on the backside of the chiller available

Chiller for temperature range 5–40°C

amh-012

Water-cooled, proven chiller for use with e.g. MDC hotplate
Temperature range can be extended to 60 °C on request

Chiller for temperature range 0–40°C

amh-032

Water-cooled, proven chiller adapted to replace

LAM TCU4080

Product specialties and highlights

  • The standardized interface is being replaced by a proprietary controller which is connected to a control touch screen on the top cover of the chiller.
    • for selection of local or remote mode
    • for adjustment of actual & target temperature
    • with password entry
    • for selection of different parameters
    • with display of warning and alarm

    An extra connector is being fixed at the housing.

  • Special components, as for example conductivity measurement, are individually available. Fluid couplings can be chosen, e.g. stainless Parker express couplings with bypass or a magnetic valve.

Configuration examples

1) amh-060 with stainless Parker express couplings with bypass and SUB-D 15-pin interface plug for replacement of HX300

 

2) amh-050 with BEAU & SUB-D 9-Pin interface plugs

Download technical data